  The Discharge Counter

lightning counterThe Discharge Counter is intended for detecting and recording the lightning strikes received by lightning protection installations such as lighting arresters. Information received makes it possible to carry out specific maintenance of equipments

Application ; The discharge counter is an essential tool for verification of the detection of lightning currents .The information received makes it possible to carry out specific maintenance of equipments (an inspection of the installation every 5 lightning strikes).

Description ; Installation ; NFC 17-102: installation at approximately 2 m from its base.Mounting in serial on the down conductor, on a compulsory path of the lightning current.Meshed cages: installation recommended of a counter on each frontage, on thedown conductors connecting to the highest points of the structure.

Principle ; the detection and logging of lightning currents passing through the protection equipments .

Advantages

  • Very strong
  • Its perfect weatherproofing makes it suitable for outdoor or indoor installation
  • Currents detected from 0.4 to 100 ka does not require any external power supply

Ordering code 

AFV 0907 CF

Counting range 

00 – 99

Counter threshold IEC 60-1 and 1180-1 (Minimal discharge current detected) 

1 kA (8/20mS) (no detection below 150 A)

Maximum discharge current detected in compliance with IEC 60-1 and 1180-1 (150 kA in 4/10 wave)

100 kA (8/20mS) -150 kA (4/10mS)

Terminal capacity 

8mm (F50mm2)

Operating temperature range 

-30 C0 ile +80 C0

Dimensions

165 x 92 x 47 mm

 

The impact controller or lightning counter is designed for detecting and counting lightning strikes received by the structures equipped with lightning conductors. It is fitted in general to a down conductor. The information received by the controller can be used for specific maintenance of the equipment. It is totally autonomous and does not require any external power supply. It is delivered with 2 collars AFJ0819RL.

 
Lightning Protections Systems
External Lightning Protection Systems
     The Simple Rod
     The Radioactive Lightning Rods
     Faraday Cage
     Stretched Line Method
     Lightning Rods
         Piezoelectric Lightning Rods
             Franklin France Lightning Rod ( SE )
         Electrostatic Active Lightining Rods
             The Tesla Lightning Rod
             Forend Petex Lightning Rod
             Forend EU Lightning Rod
             Active 2D Lightning Conductor
         Lightning Conductor Tester
         The Discharge Counter
         Lightning Rod Pole and Accessories
Surge Protection System
     Class B Surge Protection Devices
     Class C Surge Protection Devices
     Class D Surge Protection Devices
     Data Telephone Protection Systems
     Coaxial and Insulated Protection
Earthing
     Earthing Junction Conductor
     Ground Enhancement Materials
     Exothermic Welding
         Termokaynak Ürün Seçim Tablosu
Measurement Tools
Aircraft and Lighted Signal Systems
c
     The Effects of Lightning
     When Lightning Strikes
     Installation Of Lightning Rod
     Damages of Transient Overvoltage
     d
     d
     Equipotential Earthing System
     Grounding For Foundation
     Exothermic Welding and Application
   
Web Design PLUSGRUP