  Forend EU Lightning Rod

Forend Eu Air Terminals are electronic area effective Lightning Rods , and Forend Eu Active Lightning Rod is constructed of noncorrosive material to avoid Chemical corrosion. The Air Terminal’s head functions in both cases of positive lightning and negative lightning.

It has active and passive ionization electrodes.It optimizes ionization in the atmosphere in the most guarantee manner by detecting the potential differentiation between the point where the lightning conductor is located and the ground by means of its passive electrodes.

The ion productivity is maximized with the participation of internal ion generator system to this ionization dispersion. It controls the venturi system and ionization by means of the Aerodynamic structure of active ionization and direction electrodes.The resistance to Lightning Current has been tested in German BET Laboratories.It has been proved by ICMET Romania Research Development and Testing National Institute For Electrical Engineering that DL (Initiation Advance Time) of FOREND Eu is 60 ms, thus it conforms to NFC 17-102 Standards.The Air Terminal’s head have 25 - year guarantee for non-corrosion by Turkey Industry and Trade Ministry The protect of Costumer and Rivalry General Manager, with permisssion the date of 30.09.2003, The number of 16085.

The Protection Areas for Forend Eu

h (m)

(Rp)  )  Protection Radius  (m)

(ΔL=60m)

Protection Level

I

II

III

6

79

97

107

10

79

99

109

20

80

102

113

30

80

104

116

60

80

105

120

Radius Protection Of Air Terminals

The radius protection of an E.S.E. Air Terminal is calculated following,

Rp2 = h( 2D-h) + ΔL( 2D+ΔL) h≥5 mt

In this formula;

D: The advance step of The lightning or the jumping distance of lightning during way.
For protection level I D=20 m
For protection level II D=45 m
For protection level III D=60 m

ΔL (m): Calculated from V(m/µs).ΔT(/µs)

V: The moving velocity of ions occur arround air terminal to lightning and in Standart V=1m/µs
ΔT: Early streamer emission time

ΔL: The dedecting distance to lightning in ΔT times. This parameter is valiable according to the produced E.S.E air terminal and determined to test according to the valiable and special of prodection in laboratory. h: Height of the point of E.S.E air terminal (m) Rp: Radius Protection (m)

 

 
Lightning Protections Systems
External Lightning Protection Systems
     The Simple Rod
     The Radioactive Lightning Rods
     Faraday Cage
     Stretched Line Method
     Lightning Rods
         Piezoelectric Lightning Rods
             Franklin France Lightning Rod ( SE )
         Electrostatic Active Lightining Rods
             The Tesla Lightning Rod
             Forend Petex Lightning Rod
             Forend EU Lightning Rod
             Active 2D Lightning Conductor
         Lightning Conductor Tester
         The Discharge Counter
         Lightning Rod Pole and Accessories
Surge Protection System
     Class B Surge Protection Devices
     Class C Surge Protection Devices
     Class D Surge Protection Devices
     Data Telephone Protection Systems
     Coaxial and Insulated Protection
Earthing
     Earthing Junction Conductor
     Ground Enhancement Materials
     Exothermic Welding
         Termokaynak Ürün Seçim Tablosu
Measurement Tools
Aircraft and Lighted Signal Systems
c
     The Effects of Lightning
     When Lightning Strikes
     Installation Of Lightning Rod
     Damages of Transient Overvoltage
     d
     d
     Equipotential Earthing System
     Grounding For Foundation
     Exothermic Welding and Application
   
Web Design PLUSGRUP