EARTH HITESTER

 

3151 HIOKI

Ground resistance meter 3-electrode measurement on the 3151 gives greater precision !
Ground resistance measurement involves factors that are not encountered during ordinary resistance measurement, such as polarization of the earth, the influence of grounding current due to leak current and grounding voltage, and the influence of auxiliary grounding resistance. The 3151 is able to make more accurate measurements more safely under difficult conditions because it uses the alternating current potentiometer method to provide measurement accuracy, and because it contains features such as an auxiliary grounding resistance check feature and measurement frequency switching.
Basic specifications
 
Ground resistance
10 ohm (0 to 11.5 ohm), 100 ohm (0 to 115 ohm), 1000 ohm (0 to 1150 ohm), 3 ranges (±2.5 % f.s.)
Ground voltage
30 V (0 to 30 V), (±3.0 % f.s.)
Operating method
AC potentiometer method
Open circuit voltage
50 V AC max.
Measurement current
15 mA AC max. (3 mA AC max. when using the two electrode method)
Measurement frequency
575 Hz (with 3a or 2a selected) or 600 Hz (with 3b or 2b selected)
Power supply
R6P(AA) manganese batteries × 6 (at least 500 operations), or LR6(AA) alkaline batteries × 6 (at least 1400 operations)   Note:30 seconds measurement, 30 seconds off operating time
Dimensions, mass
164 mm(6.46 in)W × 119 mm(4.69 in)H × 88 mm(3.46 in)D, 800 g (28.2 oz)
Accessories
AUXILIARY EARTHING RODS 9214 (2), MEASURING CABLE 9215 (black 5 m(16.41 ft), yellow 10 m(32.81 ft), red 20 m(65.62 ft), one each CABLE WINDER 9216 × 3), CARRYING CASE 9393 (1)

EARTH HITESTER

 

3151 HIOKI

Ground resistance meter Say goodbye auxiliary grounding rods with the 3143
 
Grounding is increasingly important for the safe operation and maintenance of communications equipment and many other types of facilities. However, in an urban environment where the ground is covered with concrete or asphalt, conventional measurement methods that require inserting auxiliary grounding electrodes are difficult to use. The 3143 uses a new measurement principle that makes auxiliary grounding electrodes unnecessary, so it can be used to measure ground resistance on paved roads.
Differences between the Model 3151 and 3143
Common ground resistance meters such as the 3151 measure the resistance using a frequency between 500 Hz and several kHz.The 3143 uses a frequency between 100 kHz and 1.5 MHz, close to that of a lightning surge. Therefore, measurement errors can result if the 3143 is used in situations such as the following.In these instances, we recommend using Model 3151.
Electrical grounding or mesh grounding.
Electrical power equipment grounding.
When the measurement point is located at a distance from the insertion point of the grounding electrode.
 

4105A

EARTH TESTERS

Dust and drip proof.(designed to IEC 529 IP54)
In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.( unit can be hung from the neck for simplified measurement)
Designed to meet IEC61010-1 safety standard.
Capable of measuring earth voltage.
Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance.
Small and lightweight. Shock resistant new case material.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Measurement
Earth Resistance:0~20Ω/0~200Ω/0~2000Ω
Ranges
Earth Voltage[50,60Hz]:0~200V AC 
Accuracy
Earth Resistance:±2%rdg±0.1Ω(20Ωrange)
|±2%rdg±3dgt(200Ω/2000Ωrange)
Earth Voltage:±1%rdg±4dgt
Overload Protection
Earth Resistance:280V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage:300V AC for 1 minute
Safety Standard
IEC61010-1 CAT.III 300V Pollution Degree 2, IEC61557
Applicable Standards
IEC60529 IP54
Withstand Voltage
3700V AC for 1 minute
Power Source
R6P(AA)(1.5V) × 6
Dimensions
105(L) × 158(W) × 70(D)mm
Weight
550g approx.

Accessories
7095(Test Leads) × 1set(red-20m, yellow-10m, green-5m)
8032(Auxiliary earth spikes) × 1set
7127(Simplified measurement probe) × 1set
R6P(AA) × 6
Neck strap
Instruction Manual
Carrying Case : 4105A(Soft Case) -4105A-H(Hard Case)
 
Optional
7100(Precision measurement Cord Set) 

4102A

EARTH TESTERS

The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes.
Dust and drip proof. (designed to IEC 529 IP54)
Earth resistance value can be read directly from the scale.
Designed to meet IEC61010-1 safety standard.
Capable of measuring earth voltage.
Small and lightweight. Shock resistant new case material.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
Lead wire connection to C and P terminals and proper auxiliary earth resistance can be checked by "OK" lamp. Lead wire connection to C and E terminals is good when "OK" lamp is illuminated.
Top of Form
Measurement
Bottom of Form
Earth Resistance:0~12 Ω/0~120 Ω/0~1200 Ω
Ranges
Earth Voltage[50,60Hz]:0~30V AC
Accuracy
Earth Resistance: ±3% of full scale
Earth Voltage: ±3% of full scale
Overload Protection
Earth Resistance:276V AC for 10 seconds
across 2 of the 3 terminals
Earth Voltage:276V AC for 1 minute
Safety Standard
IEC61010-1 CAT.III 300V Pollution Degree 2, IEC61557
Applicable Standards
IEC60529 IP54
Withstand Voltage
3700V AC for 1 minute
Power Source
R6P(AA)(1.5V) × 6
Dimensions
105(L) × 158(W) × 70(D)mm
Weight
600g approx.
Accessories
7095(Test Leads) × 1set(red-20m, yellow-10m, green-5m)
8032(Auxiliary earth spikes) × 1set
7127(Simplified measurement probe) × 1set
R6P(AA) × 6
Neck strap
Instruction Manual
Carrying Case 4102A(Soft Case) - 4102A(Soft Case)
 
Optional
7100(Precision measurement Cord Set)
 
 
Lightning Protections Systems
External Lightning Protection Systems
     The Simple Rod
     The Radioactive Lightning Rods
     Faraday Cage
     Stretched Line Method
     Lightning Rods
         Piezoelectric Lightning Rods
             Franklin France Lightning Rod ( SE )
         Electrostatic Active Lightining Rods
             The Tesla Lightning Rod
             Forend Petex Lightning Rod
             Forend EU Lightning Rod
             Active 2D Lightning Conductor
         Lightning Conductor Tester
         The Discharge Counter
         Lightning Rod Pole and Accessories
Surge Protection System
     Class B Surge Protection Devices
     Class C Surge Protection Devices
     Class D Surge Protection Devices
     Data Telephone Protection Systems
     Coaxial and Insulated Protection
Earthing
     Earthing Junction Conductor
     Ground Enhancement Materials
     Exothermic Welding
         Termokaynak Ürün Seçim Tablosu
Measurement Tools
Aircraft and Lighted Signal Systems
c
     The Effects of Lightning
     When Lightning Strikes
     Installation Of Lightning Rod
     Damages of Transient Overvoltage
     d
     d
     Equipotential Earthing System
     Grounding For Foundation
     Exothermic Welding and Application
   
Web Design PLUSGRUP